Next Page service instructions |
TUBE | PIN NUMBER | PLATE CAP |
|||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | |||
AC V RES |
2 W |
0 |
(19) 13/15 KW |
2 W |
40 W |
2 W |
6.3 0 |
0 |
|||
AC V RES |
2 W |
0 |
(19) 13/15 KW |
2 W |
40 KW |
2 W |
6.3 0 |
0 |
|||
AC V RES |
55 KW |
1 MW |
230 KW |
6.3 0 |
0 0 |
18 KW |
0 |
1KW |
450 KW |
||
AC V RES |
10 KW |
1 MW |
130 KW |
6.3 0 |
0 0 |
250 KW |
*0.6 (20) 1 MW |
6.8 KW |
60 KW |
||
AC V RES |
20 KW |
1 MW |
(21) 12 KW |
6.3 0 |
0 0 |
9KW |
0 |
150 W |
100 KW |
||
AC V RES |
(22) |
(23) 0 to 500 KW |
(24) 0 |
6.3 0 |
0 0 |
(26) 270 KW |
(27) 110 KW |
(28) 220 to 485 KW |
(25) 330 W |
||
AC V RES |
2.2 KW |
5.6KW |
5.6 KW |
6.3 0 |
0 0 |
2.2 MW |
45 KW |
1 MW |
8500 W |
||
AC V RES |
(29) 0 |
(30) 2.3 MW |
230 KW |
6.3 0 |
0 0 |
68 W |
470 KW |
25 KW |
12 KW |
||
AC V RES |
1.5 KW |
0 |
6.3 0 |
(31) 2.3MW/400KW |
(32) 8.5/300 KW |
100 KW |
(33) 1 KW |
* OFF - ON - NB - CAL switch in the CAL position ** EMISSION switch in TUNE position | |
(1) (2) (3) (4) (6) (7) (8) (9) |
Voltage at V1-1 may vary more than 20 %. Voltage depends on RCVR GAIN ADJ. (R132) setting. Voltage and resistance at V1 - 2 may vary more than 20%. Voltage depends on RCVR GAIN ADJ (R132) anf S METER ZERO (NULL) settings. Resistance depends on S METER ZERO (R121) setting. Voltage at V2 - 3 may vary more than 20%.Voltage and resistance depends on RCVR GAIN ADJ. (R132) setting. Resistance at V2 - 2 is 640 KW (± 20%) if R51 and R52 are 390 KW each. Refer to =1=> in illustration section. Voltage and resiostance at V3 - 2 may vary more than 20%. Voltage and resistance depend on S METER ZERO (R121) setting. Voltage at V3 - 7 may vary more than 20%, Voltage deepends on MIC GAIN (R6) setting. Voltage and resistance at V3-8 may vary more than 20%. Voltage depends on MIC GAIN (R8) setting. Resistance depends on polarity of Ohm meter and value of R18 used. Smaller resistance is with positive lead of ohmmeter connected to ground. Resistance is 22.5 KW, or 31.5 KW if R18 is 47 KW. Refer to =12=> in illustration section. Voltage at V3 - 9 may vary more than 20%. Voltage and resistance depend on MIC GAIN (R8) setting. Voltage at V4 - 2 is 0/95 Vdc (± 20%) and resistance is 33 KW (± 20%) if R118 is 47KW . Refer to =12=> in illustration section. |