NEXT Page 21 of 25

Section V
AN-08-10-112

TABLE G -- ALIGNMENT CHART part 2

Follow alignment in order from left to right. Start with 3rd I-F adjusment in first column, then 2nd I-F, etc. Connect signal generator to ground post of receiver using a short heavy lead. Allow receiver and signal generator to heat up for several minutes.

RECEIVER CONTROLS215 kc. Osc. PadderNo.2 BandNo.3 BandNo.4 Band No.5 BandNo.6 Band
OFFOFFOFFOFFOFFOFF
OUTOUTOUTOUTOUTOUT
MVCMVCMVCMVCMVCMVC
MaximumMaximumMaximumMaximumMaximumMaximum
No.1 Band 200-500 kc.No. 2 Band 1.5-3.5 Mc No. 3 Band 3.5-6 Mc No. 4 Band 6-9.5 Mc No. 5 Band 9.5-13.5 Mc. No. 6 Band 13.5-18 Mc.
215 kc.3.5 Mc5.7 Mc9.0 Mc13 Mc17.3 Mc
Antenna PostAntenna PostAntenna Post.Antenna PostAntenna PostAntenna Post
100 MMF.100 MMF100 MMF100 MMF100 MMF100 MMF
Shut Off Signal Generator See Note B.3.3 Mc5.7 Mc9.0 Mc13.0 Mc17.3 Mc.
Procedure 9 Microvolt See Note A9 Microvolt See Note A9 Microvolt See Note A9 Microvolts See Note A9 Microvolt See Note A
21 kc. oscillator Padder see Fig 31No.2 Trimmers on Osc. Det. R.f. and antenna Units. See Fig. 31No.3 Trimmers on Osc. Det. R.f. and antenna Units. See Fig. 31No. 4 Trimmers on Osc. Det. R.f. and antenna Units. See Fig. 31No. 5 Trimmers on Osc. Det. R.F. and Antenna Units See Fig. 31No. 6 Trimmers on Osc. Det. R.f. and antenna Units. See Fig. 31
Adjust 21kc. osc. Padder to max. out-put. repeat No.1 Band adjustment & 215 kc. osc. Padder adjusments 2 or 3 times to insure correct tracking and dial calibration. Adjust No.2 Trimmer on Osc. Unit to max. out-put. then adjust Trimmers on Det. R.F. and Antenna Units, in that order to maximum out-put, and decrease signal as required to maintain 10 milliwatts output. Repeat above Adjust No.3 Trimmer on Osc. Unit to max. out-put. then adjust Trimmers on Det. R.F. and Antenna Units, in that order to maximum out-put, and decrease signal as required to maintain 10 milliwatts output. Repeat above Adjust No.4 Trimmer on Osc. Unit to max. out-put. then adjust Trimmers on Det. R.F. and Antenna Units, in that order to maximum out-put, and decrease signal as required to maintain 10 milliwatts output. Repeat above Adjust No.5 Trimmer on Osc. Unit to max. out-put. then adjust Trimmers on Det. R.F. and Antenna Units, in that order to maximum out-put, and decrease signal as required to maintain 10 milliwatts output. Repeat above Adjust No.6 Trimmer on Osc. Unit to max. out-put. then adjust Trimmers on Det. R.F. and Antenna Units, in that order to maximum out-put, and decrease signal as required to maintain 10 milliwatts output. Repeat above
NOTE A -- SENSITIVITY

Adjust signal generator until receiver output is 10 milliwatts. Turn off modulation of signal generator. Turn down receiver volume control until 0.3 milliwatts of noise output is reached. Turn on generator modulation again, and raise generator output to obtain 10 milliwatts on output meter.

NOTE B

This adjusment uses the noise developed in the receiver as only signal

Revised 18 December 1943

NEXT Page 21 of 25