NEXT Page 18 of 25

Section V
AN=08-10-112

TABLE E -- ADDITIONAL POINTS TO MAKE CONTINUITY RESISTANCE READINGS TO GROUND

RESISTANCE READINGS MADE UNDER THE SAME CONDITIONS
AS FOR TUBE SOCKET READINGS


POWER CONNECTOR (175) OUTPUT TRANSFORMER and CHOKE (155-A and B) DYNAMOTOR TERMINAL STRIP
Terminal Numbers on Connector
Resistance
Terminal Numbers on Unit
Resistance
Readings from low Voltage in High Voltage End
1.

2.

3.

4.

5.

6

7.

8.

150 ohms

500 ohms

1.5 ohms Note A

1.5 ohms Note A

0

500,000 ohms

0

0

1.

2.

3.

4.

5.

6

16 ohms

150 ohms

500 ohms

1200 ohms

25 ohms

270 ohms

0

1.5 ohms Note A

1.5 ohms Note A

270 ohms

500 ohms

Note A -- This reading may be found to vary and may be as high as 11 ohms. This condition is normal and jarring the dynamotor will often return the reading to approaximately the value shown.

Figure 12

Figure 12 -- Socket Voltages

NEXT Page 18 of 25